Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Methods Mol Biol ; 2742: 105-122, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38165619

RESUMO

The combination of advanced mass spectrometry and enrichment-based sample preparation methods has enhanced analytical capabilities in clinical proteomics. In this chapter, we describe a method of proteome analysis to identify Borrelia-derived peptides in urine that includes a sample affinity enrichment method coupled with liquid chromatography tandem mass spectrometry analysis and a bioinformatic peptide authentication algorithm.


Assuntos
Borrelia , Humanos , Espectrometria de Massas em Tandem/métodos , Peptídeos/química , Cromatografia Líquida/métodos , Proteoma/análise
2.
J Extracell Vesicles ; 11(7): e12244, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35879267

RESUMO

We characterized the in vivo interstitial fluid (IF) content of extracellular vesicles (EVs) using the GFP-4T1 syngeneic murine cancer model to study EVs in-transit to the draining lymph node. GFP labelling confirmed the IF EV tumour cell origin. Molecular analysis revealed an abundance of IF EV-associated proteins specifically involved in mitophagy and secretory autophagy. A set of proteins required for sequential steps of fission-induced mitophagy preferentially populated the CD81+/PD-L1+ IF EVs; PINK1, TOM20, and ARIH1 E3 ubiquitin ligase (required for Parkin-independent mitophagy), DRP1 and FIS1 (mitochondrial peripheral fission), VDAC-1 (ubiquitination state triggers mitophagy away from apoptosis), VPS35, SEC22b, and Rab33b (vacuolar sorting). Comparing in vivo IF EVs to in vitro EVs revealed 40% concordance, with an elevation of mitophagy proteins in the CD81+ EVs for both murine and human cell lines subjected to metabolic stress. The export of cellular mitochondria proteins to CD81+ EVs was confirmed by density gradient isolation from the bulk EV isolate followed by anti-CD81 immunoprecipitation, molecular sieve chromatography, and MitoTracker export into CD81+ EVs. We propose the 4T1 in vivo model as a versatile tool to functionally characterize IF EVs. IF EV export of fission mitophagy proteins has broad implications for mitochondrial function and cellular immunology.


Assuntos
Vesículas Extracelulares , Neoplasias , Animais , Líquido Extracelular/metabolismo , Vesículas Extracelulares/metabolismo , Humanos , Camundongos , Mitofagia , Proteínas Quinases/metabolismo , Ubiquitina-Proteína Ligases/metabolismo , Proteínas de Transporte Vesicular
3.
Expert Rev Proteomics ; 18(10): 845-861, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34607525

RESUMO

INTRODUCTION: Laser Capture Microdissection (LCM) uses a laser to isolate, or capture, specific cells of interest in a complex heterogeneous tissue section, under direct microscopic visualization. Recently, there has been a surge of publications using LCM for tissue spatial molecular profiling relevant to a wide range of research topics. AREAS COVERED: We summarize the many advances in tissue Laser Capture Proteomics (LCP) using mass spectrometry for discovery, and protein arrays for signal pathway network mapping. This review emphasizes: a) transition of LCM phosphoproteomics from the lab to the clinic for individualized cancer therapy, and b) the emerging frontier of LCM single cell molecular analysis combining proteomics with genomic, and transcriptomic analysis. The search strategy was based on the combination of MeSH terms with expert refinement. EXPERT OPINION: LCM is complemented by a rich set of instruments, methodology protocols, and analytical A.I. (artificial intelligence) software for basic and translational research. Resolution is advancing to the tissue single cell level. A vision for the future evolution of LCM is presented. Emerging LCM technology is combining digital and AI guided remote imaging with automation, and telepathology, to a achieve multi-omic profiling that was not previously possible.


Assuntos
Medicina de Precisão , Proteômica , Inteligência Artificial , Microdissecção e Captura a Laser , Lasers
5.
Sci Rep ; 10(1): 13944, 2020 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-32811861

RESUMO

An accurate urine test for diverse populations with active tuberculosis could be transformative for preventing TB deaths. Urinary liporabinomannan (LAM) testing has been previously restricted to HIV co-infected TB patients. In this study we evaluate urinary LAM in HIV negative, pediatric and adult, pulmonary and extrapulmonary tuberculosis patients. We measured 430 microbiologically confirmed pretreatment tuberculosis patients and controls from Peru, Guinea Bissau, Venezuela, Uganda and the United States using three monoclonal antibodies, MoAb1, CS35, and A194, which recognize distinct LAM epitopes, a one-sided immunoassay, and blinded cohorts. We evaluated sources of assay variability and comorbidities (HIV and diabetes). All antibodies successfully discriminated TB positive from TB negative patients. ROAUC from the average of three antibodies' responses was 0.90; 95% CI 0.87-0.93, 90% sensitivity, 73.5% specificity (80 pg/mL). MoAb1, recognizing the 5-methylthio-D-xylofuranose(MTX)-mannose(Man) cap epitope, performed the best, was less influenced by glycosuria and identified culture positive pediatric (N = 19) and extrapulmonary (N = 24) patients with high accuracy (ROAUC 0.87, 95% CI 0.77-0.98, 0.90 sensitivity 0.80 specificity at 80 pg/mL; ROAUC = 0.96, 95% CI 0.92-0.99, 96% sensitivity, 80% specificity at 82 pg/mL, respectively). The MoAb1 antibody, recognizing the MTX-Man cap epitope, is a novel analyte for active TB detection in pediatric and extrapulmonary disease.


Assuntos
Lipopolissacarídeos/análise , Tuberculose/diagnóstico , Tuberculose/imunologia , Adulto , Coinfecção/urina , Epitopos/imunologia , Feminino , Guiné-Bissau , Infecções por HIV/urina , Humanos , Imunoensaio/métodos , Testes Imunológicos/métodos , Lipopolissacarídeos/imunologia , Lipopolissacarídeos/urina , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/imunologia , Peru , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Tuberculose/classificação , Tuberculose Pulmonar/microbiologia , Uganda , Estados Unidos , Venezuela
6.
Adv Exp Med Biol ; 1188: 1-19, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31820380

RESUMO

RPPA technology has graduated from a research tool to an essential component of clinical drug discovery research and personalized medicine. Next generations of RPPA technology will be a single clinical instrument that integrates all the steps of the workflow.


Assuntos
Medicina de Precisão , Análise Serial de Proteínas , Proteômica , Medicina de Precisão/instrumentação , Medicina de Precisão/tendências , Análise Serial de Proteínas/normas , Análise Serial de Proteínas/tendências , Pesquisa/instrumentação , Pesquisa/tendências
7.
Expert Rev Proteomics ; 15(4): 353-366, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29542338

RESUMO

INTRODUCTION: Mass spectrometry (MS) is the premier tool for discovering novel disease-associated protein biomarkers. Unfortunately, when applied to complex body fluid samples, MS has poor sensitivity for the detection of low abundance biomarkers (≪10 ng/mL), derived directly from the diseased tissue cells or pathogens. Areas covered: Herein we discuss the strengths and drawbacks of technologies used to concentrate low abundance analytes in body fluids, with the aim to improve the effective sensitivity for MS discovery. Solvent removal by dry-down or dialysis, and immune-depletion of high abundance serum or plasma proteins, is shown to have disadvantages compared to positive selection of the candidate biomarkers by affinity enrichment. A theoretical analysis of affinity enrichment reveals that the yield for low abundance biomarkers is a direct function of the binding affinity (Association/Dissociation rates) used for biomarker capture. In addition, a high affinity capture pre processing step can effectively dissociate the candidate biomarker from partitioning with high abundance proteins such as albumin. Expert commentary: Properly designed high affinity capture materials can enrich the yield of low abundance (0.1-10 picograms/mL) candidate biomarkers for MS detection. Affinity capture and concentration, as an upfront step in sample preparation for MS, combined with MS advances in software and hardware that improve the resolution of the chromatographic separation can yield a transformative new class of low abundance biomarkers predicting disease risk or disease latency.


Assuntos
Biomarcadores/metabolismo , Espectrometria de Massas/métodos , Doenças Transmissíveis/metabolismo , Humanos , Doença de Lyme/metabolismo , Nanotecnologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...